Seismic joint system for joints up to 1000 mm subject to high movements up to +/ – 950 mm, specially designed for base isolated buildings. Suitable for loads by cars. The system consists of a rectangular section devoid of underfloor brackets and visible screws. Central plate rigid and antislip, made of knurled aluminium. Gaskets made of rubber with high resistance to vertical loads. The system supports the movement in 3 directions, a special system of sliding on rollers allows longitudinal movements.
• Available versions with increased last movement U or joint width G
• System height only 50 mm
• No visible screws.
• Bar length 3 m.
• Self-tapping fixing l= 50 mm
• Black gasket.
• “Bump less” transit
On request: profiles to length,special pieces, floor / wall versions.
| Model / System | G | L | H | Thermal Movement | Seismic Movement | Ultimate Movement |
|---|---|---|---|---|---|---|
| K 3D G100 M50 | 100 | 340 | 50 | 20 (+/- 10) | 100 (+/- 50) | |
| K 3D G600 M50 | 600 | 840 | 50 | 20 (+/- 10) | 100 (+/- 50) | |
| K 3D G150 M50 U100 | 150 | 440 | 50 | 20 (+/- 10) | 100 (+/- 50) | 200 (+/- 100) |
| K 3D G600 M50 U550 | 600 | 1340 | 50 | 20 (+/- 10) | 100 (+/- 50) | 1100 (+/- 550) |
| K 3D G150 M100 | 150 | 500 | 50 | 40 (+/- 20) | 200 (+/- 100) | |
| K 3D G600 M100 | 600 | 950 | 50 | 40 (+/- 20) | 200 (+/- 100) | |
| K 3D G200 M100 U150 | 200 | 600 | 50 | 40 (+/- 20) | 200 (+/- 100) | 300 (+/- 150) |
| K 3D G600 M100 U550 | 600 | 1400 | 50 | 40 (+/- 20) | 200 (+/- 100) | 1100 (+/- 550) |
| K 3D G250 M200 | 250 | 900 | 50 | 100 (+/- 50) | 400 (+/- 200) | |
| K 3D G600 M200 | 600 | 1250 | 50 | 100 (+/- 50) | 400 (+/- 200) | |
| K 3D G250 M200 U200 | 250 | 900 | 50 | 100 (+/- 50) | 400 (+/- 200) | 400 (+/- 200) |
| K 3D G600 M200 U550 | 600 | 1600 | 50 | 100 (+/- 50) | 400 (+/- 200) | 1100 (+/- 550) |
Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.
Download PDF arrow_forwardLoad-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.
Download PDF arrow_forwardSpecifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.
Coming soon hourglass_emptyDetailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.
Coming soon hourglass_emptyOur technical team responds within 24 hours. Free consultation.