Fire Barriers

K FIRE CABLE


fireproof insulation expansion joint coverjoint
K FIRE CABLE
Certified fire-rated floor-wall Scope
EI 180 Usage
Woven mineral fiber Finish

Description

Fire barrier system for expansion joints in wall or floor, joint width up to 100 mm. The system consists of a flexible cord made ​​of mineral fiber non-toxic, not subject to putrefaction. The junction between consecutive rolls is through simple overlap. System certified according to the current European standard UNI EN 1366-4. No glue or fixings needed,installs easily by pushing it into the joint.

• Available separate certifications for installation on the wall or floor.

• Ease of installation, no glue or sealants required by certificationd. If used for the ceiling, we recommend the use of cover joints.

On request : pieces to length.

Dimensions & Technical Variants

Model / System G Diameter Roll Length Total Thermal Movement Total Seismic Movement
K FIRE CABLE 20 10 20 50 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 30 20 30 50 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 40 30 40 20 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 50 40 50 20 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 60 50 60 20 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 70 60 70 20 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 80 70 80 15 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 90 80 90 15 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 100 90 100 10 20 (+/- 10) 20 (+/- 10)
K FIRE CABLE 120 100 120 5 30 (+/- 15) 30 (+/- 15)

Product Section

K FIRE CABLE - Technical section view
Documents and resources

Technical documentation and resources

description
PDF

Technical Data Sheet

Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.

Download PDF arrow_forward
assignment
PDF

Loads

Load-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.

Download PDF arrow_forward
layers
DWG/BIM

Specifications and Stratigraphy

Specifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.

Coming soon hourglass_empty
menu_book
Guide

Application Guides

Detailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.

Coming soon hourglass_empty

Want to know more about K FIRE CABLE?

Our technical team responds within 24 hours. Free consultation.

More Fire Barriers products