Expansion joint system for floor joints, subject to high movement. Suitable for pedestrian traffic areas. The system consists of a central pan made of galvanized sheet, to be filled with reinforced concrete (thickness min. 40 mm) and/or floor finish material, two rubber gaskets. Exceeded the thermal movement, the central pan pops up until its thickness. the maximum movement of gaskets is regulated by metal cables that prevent the fall of the pan.
• Reduced visual impact.
• Bar length 3 m.
• L = 50/60 mm self-tapping fixing.
• Black gaskets.
• Custom heights available.
• Custom ultimate movement available U≤G
On request: pro les to length, special pieces, oor / wall versions, high resistance versions (Kit R).
| Model / System | G | L | Lc | H | Thermal Movement | Seismic Movement | Ultimate Movement |
|---|---|---|---|---|---|---|---|
| K UP G100 H60 M50 U100 | 100 | 400 | 300 | 60 | 40 (+/- 20) | 100 (+/- 50) | 200 (+/- 100) |
| K UP G150 H60 M50 U150 | 150 | 500 | 400 | 60 | 40 (+/- 20) | 100 (+/- 50) | 300 (+/- 150) |
| K UP G200 H60 M50 U200 | 200 | 600 | 500 | 60 | 40 (+/- 20) | 100 (+/- 50) | 400 (+/- 200) |
| K UP G250 H60 M50 U250 | 250 | 700 | 600 | 60 | 40 (+/- 20) | 100 (+/- 50) | 500 (+/- 250) |
| K UP G300 H60 M50 U300 | 300 | 800 | 700 | 60 | 40 (+/- 20) | 100 (+/- 50) | 600 (+/- 300) |
| K UP G100 H80 M50 U100 | 100 | 450 | 350 | 80 | 40 (+/- 20) | 100 (+/- 50) | 200 (+/- 100) |
| K UP G150 H80 M50 U150 | 150 | 550 | 450 | 80 | 40 (+/- 20) | 100 (+/- 50) | 300 (+/- 150) |
| K UP G200 H80 M50 U200 | 200 | 650 | 550 | 80 | 40 (+/- 20) | 100 (+/- 50) | 400 (+/- 200) |
| K UP G250 H80 M50 U250 | 250 | 750 | 650 | 80 | 40 (+/- 20) | 100 (+/- 50) | 500 (+/- 250) |
| K UP G300 H80 M50 U300 | 300 | 850 | 750 | 80 | 40 (+/- 20) | 100 (+/- 50) | 600 (+/- 300) |
| K UP G350 H80 M50 U350 | 350 | 950 | 850 | 80 | 40 (+/- 20) | 100 (+/- 50) | 700 (+/- 350) |
| K UP G400 H80 M50 U400 | 400 | 1050 | 950 | 80 | 40 (+/- 20) | 100 (+/- 50) | 800 (+/- 400) |
| K UP G450 H80 M50 U450 | 450 | 1150 | 1050 | 80 | 40 (+/- 20) | 100 (+/- 50) | 900 (+/- 450) |
| K UP G500 H80 M50 U500 | 500 | 1250 | 1150 | 80 | 40 (+/- 20) | 100 (+/- 50) | 1000 (+/- 500) |
| K UP G550 H80 M50 U550 | 550 | 1350 | 1250 | 80 | 40 (+/- 20) | 100 (+/- 50) | 1100 (+/- 550) |
| K UP G600 H80 M50 U600 | 600 | 1450 | 1350 | 80 | 40 (+/- 20) | 100 (+/- 50) | 1200 (+/- 600) |
Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.
Download PDF arrow_forwardLoad-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.
Download PDF arrow_forwardSpecifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.
Coming soon hourglass_emptyDetailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.
Coming soon hourglass_emptyOur technical team responds within 24 hours. Free consultation.
DescriptionExpansion joint system for floor joints, subject to high movement. Suitable for pedestria…
DescriptionExpansion joint system for floor joints, subject to high movement. Suitable for pedestria…
DescriptionExpansion joint system for floor joints, subject to high movement. Suitable for pedestria…