Expansion Joint system for joints up to 600 mm subject to high movements up to + / -50 mm, suitable for areas susceptible to significant overcrowding. The system consists of a central box made of galvanized sheet, to be filled with reinforced concrete (thickness min. 40 mm) and flooring, adjunct to the expansion joint system, devoid of underfloor brackets. Ideal for floor/wall joints. For H = 60 max G = 300. For H ≥ 80, 200<G<600. Available different widths 200≤G≤600, every 50. Values in mm.
• High movements.
• Bar length 4 m.
• L = 50/60 mm self-tapping fixing.
On request: profiles to length, special pieces, corner versions.
| Model / System | G | L | Lc | H | Thermal Movement | Seismic Movement |
|---|---|---|---|---|---|---|
| K MALL1 G200 H60 | 200 | 560 | 354 | 60 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G250 H60 | 250 | 610 | 404 | 60 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G300 H60 | 300 | 660 | 454 | 60 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G200 H80 | 200 | 560 | 354 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G250 H80 | 250 | 610 | 404 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G300 H80 | 300 | 660 | 454 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G350 H80 | 350 | 710 | 504 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G400 H80 | 400 | 760 | 554 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G500 H80 | 500 | 860 | 654 | 80 | 60 (+/- 30) | 100 (+/- 50) |
| K MALL1 G600 H80 | 600 | 960 | 754 | 80 | 60 (+/- 30) | 100 (+/- 50) |
Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.
Download PDF arrow_forwardLoad-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.
Download PDF arrow_forwardSpecifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.
Coming soon hourglass_emptyDetailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.
Coming soon hourglass_emptyOur technical team responds within 24 hours. Free consultation.
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …