Seismic floors

K SISM M40


expansion joint coverjoint jointing system seismic floors
K SISM M40
Floor Scope
Pedestrian Usage
Rubber - Aluminum Finish

Description

Expansion Joint system for joints up to 600 mm subject to high movements up to + / -40 mm,suitable for pedestrian traffic areas. . The system consists of a central box made of galvanized sheet, to be filled with reinforced concrete (thickness min. 40 mm) and flooring. Two rubber gaskets.

• Reduced visual impact.
• Bar length 4 m.
• Self-tapping fixing l= 50 mm
• Black Gasket .
• Side reinforcements for H = 80 mm.

On request: profiles to length,special pieces, floor / wall versions. Available gasket: gray, beige, smooth gray (Thermal mov. reduced).

Dimensions & Technical Variants

Model / System G L Lt Lp H Total Thermal Movement Total Seismic Movement
K SISM G100 H50 M40 100 55+55 480 250 50 40 (+/- 20) 80 (+/- 40)
K SISM G150 H50 M40 150 55+55 530 300 50 40 (+/- 20) 80 (+/- 40)
K SISM G200 H50 M40 200 55+55 580 350 50 40 (+/- 20) 80 (+/- 40)
K SISM G250 H50 M40 250 55+55 630 400 50 40 (+/- 20) 80 (+/- 40)
K SISM G300 H50 M40 300 55+55 680 450 50 40 (+/- 20) 80 (+/- 40)
K SISM G100 H80 M40 100 55+55 490 250 80 40 (+/- 20) 80 (+/- 40)
K SISM G150 H80 M40 150 55+55 540 300 80 40 (+/- 20) 80 (+/- 40)
K SISM G200 H80 M40 200 55+55 590 350 80 40 (+/- 20) 80 (+/- 40)
K SISM G250 H80 M40 250 55+55 640 400 80 40 (+/- 20) 80 (+/- 40)
K SISM G300 H80 M40 300 55+55 690 450 80 40 (+/- 20) 80 (+/- 40)

Product Section

K SISM M40 - Technical section view
Documents and resources

Technical documentation and resources

description
PDF

Technical Data Sheet

Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.

Download PDF arrow_forward
assignment
PDF

Loads

Load-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.

Download PDF arrow_forward
layers
DWG/BIM

Specifications and Stratigraphy

Specifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.

Coming soon hourglass_empty
menu_book
Guide

Application Guides

Detailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.

Coming soon hourglass_empty

Want to know more about K SISM M40?

Our technical team responds within 24 hours. Free consultation.