Expansion Joint system for joints up to 600 mm subject to high movements up to + / -50 mm, suitable for pedestrian traffic areas. . The system consists of a central box made of galvanized sheet, to be filled with reinforced concrete (thickness min. 40 mm) and flooring. Exceeded the thermal movement the box rises by 5 mm Two rubber gaskets.
• Reduced visual impact.
• Bar length 4 m.
• Self-tapping fixing l= 50 mm
• Black Gasket .
• Side reinforcements for H = 82 mm.
On request: profiles to length,special pieces, floor / wall versions. Available gasket: gray, beige, smooth gray (Thermal mov. reduced).
| Model / System | G | L | Lt | Lp | H | Thermal Movement | Seismic Movement |
|---|---|---|---|---|---|---|---|
| K SISM G100 H52 M50 | 100 | 55+55 | 490 | 250 | 52 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G150 H52 M50 | 150 | 55+55 | 540 | 300 | 52 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G200 H52 M50 | 200 | 55+55 | 590 | 350 | 52 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G250 H52 M50 | 250 | 55+55 | 640 | 400 | 52 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G300 H52 M50 | 300 | 55+55 | 690 | 450 | 52 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G100 H82 M50 | 100 | 55+55 | 500 | 250 | 82 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G150 H82 M50 | 150 | 55+55 | 550 | 300 | 82 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G200 H82 M50 | 200 | 55+55 | 600 | 350 | 82 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G250 H82 M50 | 250 | 55+55 | 650 | 400 | 82 | 50 (+/- 25) | 100 (+/- 50) |
| K SISM G300 H82 M50 | 300 | 55+55 | 700 | 450 | 82 | 50 (+/- 25) | 100 (+/- 50) |
Technical details, range of compensated movements (thermal and seismic), and material specifications for each expansion joint profile.
Download PDF arrow_forwardLoad-bearing tables, certified transit (pedestrian, forklifts, heavy duty traffic), and structural resistances in full compliance with NTC 2018 standards.
Download PDF arrow_forwardSpecifications, DWG drawings, and BIM models to seamlessly integrate seismic and fire barrier joint systems directly into your architectural designs.
Coming soon hourglass_emptyDetailed installation sheets to ensure the maximum efficiency and safety of our floor and wall joint systems.
Coming soon hourglass_emptyOur technical team responds within 24 hours. Free consultation.
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …
Description Expansion Joint system for joints up to 600 mm subject to high movements up to …